Products

Superior +

Product Specifications

  • Inner Tank Material : 2 mm Mild Steel
  • Inner Coating : Special Epoxy Gloss Lining
  • Outer Cover : 0.35 mm Pre-coated Galvanized iron
  • Insulation : 50 mm Puf
  • Stand : Powder coated M S Structure
  • Connection : 1 inch (inlet & outlet)
  • Electric Backup Provision : As Per Requirement


Model : 100 150 200 250 300 500
Tubes : 11 16 21 25 30 30

Technical Specifications

Hot Water Storage Tank
1. Inner Tank Metrial:
a. Mild Steel 2 MM
b.Mild Steel 1.6 MM
c. Galvanised Iron 2 MM
d. To Increase Anticorrison Properties Of Inner Tank Special Class Linning Is Applied
2. Hot Water Tank Insulation:
a. High Density Injected PUF Insulation: 50 MM
b. Insulation Density: 48 KG/Cubic CM
c. Thinkness Btw Inner Outer Tank 50 MM ensures Max Heat Resiantence Every Season Upto 72 hrs
3. Outer Cover:
Pre-Coated With Lamination G.I Sheet
b. 0.3 MM Thickness
4. Tank Stand & Support:
a. Support Structure Mild Steel Angle
b. MS Angle With Podwer Coating
c. The Stucture In A Postion With Stant Wild Veliocity 100 Km/Hr
5. Working Pressure Of the System
a. Normal Gravity Feed Less Then 1Kg/Cm2
6. Tank Test Pressure
a. Factory Pressure Tested For 2Kg/Cm2
Solar Evaculated Tube
1. ETC:
a. 3 Target With Copper Coating and Selective Absorptive Graded AL-N
b. Double Walled Glass Outer Tube Diameter 58 MM
c. Vacum Insulation Btw Inner & Outer Tube
2. Tube Dimension:
a. 58×1800 MM
b. 58×2100 MM
3.Tube Assemble Frame:
a. Mild Steel Section
b. Anti-Corision Coating
Backup Provision (Optional)
1. ISI Mark Electrical heater With Thermostat
a. 1.5 KW
b. 2 KW

Download Catelogue

Advantages

  • Simple to construct and install.
  • No or negligible running cost.
  • Almost maintenance free.
  • Cost is low and economically competitive with electric water heating system.
  • It saves time high grade form of electric energy
  • Required low temperature up to 100° C can be achieved by simple flat plate collector.


Ultimate - SL

Product Specifications

  • Inner Tank Material : 1.6 mm Mild Steel
  • Inner Coating : Special Epoxy Gloss Lining
  • Outer Cover : 0.35 mm Pre-coated Galvanized iron
  • Insulation : 50 mm Puf
  • Stand : Powder coated M S Structure
  • Connection : 1 inch M S pipe (inlet & outlet)


Model : 100 150 200 250 300 500
Tubes : 10 15 20 25 30 30

Technical Specifications

Hot Water Storage Tank
1. Inner Tank Metrial:
a. Mild Steel 2 MM
b.Mild Steel 1.6 MM
c. Galvanised Iron 2 MM
d. To Increase Anticorrison Properties Of Inner Tank Special Class Linning Is Applied
2. Hot Water Tank Insulation:
a. High Density Injected PUF Insulation: 50 MM
b. Insulation Density: 48 KG/Cubic CM
c. Thinkness Btw Inner Outer Tank 50 MM ensures Max Heat Resiantence Every Season Upto 72 hrs
3. Outer Cover:
Pre-Coated With Lamination G.I Sheet
b. 0.3 MM Thickness
4. Tank Stand & Support:
a. Support Structure Mild Steel Angle
b. MS Angle With Podwer Coating
c. The Stucture In A Postion With Stant Wild Veliocity 100 Km/Hr
5. Working Pressure Of the System
a. Normal Gravity Feed Less Then 1Kg/Cm2
6. Tank Test Pressure
a. Factory Pressure Tested For 2Kg/Cm2
Solar Evaculated Tube
1. ETC:
a. 3 Target With Copper Coating and Selective Absorptive Graded AL-N
b. Double Walled Glass Outer Tube Diameter 58MM
c. Vacum Insulation Btw Inner & Outer Tube
2. Tube Dimension:
a. 58×1800 MM
b. 58×2100 MM
3.Tube Assemble Frame:
a. Mild Steel Section
b. Anti-Corision Coating
Backup Provision (Optional)
1. ISI Mark Electrical heater With Thermostat
a. 1.5 KW
b. 2 KW

Advantages

  • Simple to construct and install.
  • No or negligible running cost.
  • Almost maintenance free.
  • Cost is low and economically competitive with electric water heating system.
  • It saves time high grade form of electric energy
  • Required low temperature up to 100° C can be achieved by simple flat plate collector.


GI Model

Product Specifications

  • Inner Tank Material : 2 mm Galvanized Iron
  • Outer Cover : 0.35 mm Pre-coated Galvanized iron
  • Insulation : 50 mm Puf
  • Stand : Powder coated M S Structure
  • Connection : 1 inch GI pipe (inlet & outlet)


Model : 100 150 200 250 300 500
Tubes : 10 15 20 25 30 30

Technical Specifications

Hot Water Storage Tank
1. Inner Tank Metrial:
a. Mild Steel 2 MM
b.Mild Steel 1.6 MM
c. Galvanised Iron 2 MM
d. To Increase Anticorrison Properties Of Inner Tank Special Class Linning Is Applied
2. Hot Water Tank Insulation:
a. High Density Injected PUF Insulation: 50 MM
b. Insulation Density: 48 KG/Cubic CM
c. Thinkness Btw Inner Outer Tank 50MM ensures Max Heat Resiantence Every Season Upto 72hrs
3. Outer Cover:
Pre-Coated With Lamination G.I Sheet
b. 0.3 MM Thickness
4. Tank Stand & Support:
a. Support Structure Mild Steel Angle
b. MS Angle With Podwer Coating
c. The Stucture In A Postion With Stant Wild Veliocity 100 Km/Hr
5. Working Pressure Of the System
a. Normal Gravity Feed Less Then 1Kg/Cm2
6. Tank Test Pressure
a. Factory Pressure Tested For 2Kg/Cm2
Solar Evaculated Tube
1. ETC:
a. 3 Target With Copper Coating and Selective Absorptive Graded AL-N
b. Double Walled Glass Outer Tube Diameter 58MM
c. Vacum Insulation Btw Inner & Outer Tube
2. Tube Dimension:
a. 58×1800 MM
b. 58×2100 MM
3.Tube Assemble Frame:
a. Mild Steel Section
b. Anti-Corision Coating
Backup Provision (Optional)
1. ISI Mark Electrical heater With Thermostat
a. 1.5 KW
b. 2 KW

Advantages

  • Simple to construct and install.
  • No or negligible running cost.
  • Almost maintenance free.
  • Cost is low and economically competitive with electric water heating system.
  • It saves time high grade form of electric energy
  • Required low temperature up to 100° C can be achieved by simple flat plate collector.